TECHNICAL SPECIFICATIONS
Sizes of the Essy LT design radiator:
Heights: 200mm high, 300mm high, 400mm high, 500mm high, 565mm high, 595mm high, 600mm high, 635mm high, 665mm high, 685mm high, 750mm high, 765mm high, 795mm high, 865mm high, 885mm high, 900mm high, 1000mm high, 1200mm high, 1500mm high, 1800mm high, 2000mm high
Widths (vent valves: plus 15mm!): 114mm wide,159mm wide, 204mm wide, 249mm wide, 294mm wide, 339mm wide, 384mm wide, 429mm wide, 474mm wide, 519mm wide, 564mm wide, 609mm wide, 654mm wide, 699mm wide, 744mm wide, 789mm wide, 834mm wide, 879mm wide, 924mm wide, 969mm wide, 1014mm wide, 1059mm wide, 1104mm wide, 1149mm wide, 1194mm wide, 1239mm wide, 1284mm wide, 1329mm wide, 1374mm wide, 1419mm wide, 1464mm wide, 1509mm wide, 1554mm wide, 1599mm wide, 1644mm wide, 1689mm wide, 1734mm wide, 1779mm wide, 1824mm wide
Versions: 2 columns, 3 columns, 4 columns, 5 columns and 6 columns
Technical specifications:
All radiators have been manufactured and tested in accordance with DIN EN 442.
Operating temperatures: 55/45/20°C (Δt30°C)
Valves: These design radiators are not supplied with valves.
Available connections:
A) 4 x 1/2" BSP side connections - Centre-to-centre distance of connections: nominal height -67mm
B) 2 x 1/2" BSP bottom opposite end (BOE) connections - Centre-to-centre distance of connections: nominal width + valves
Maximum operating pressure: 8 bar
Maximum water temperature: 95°C
Air vent: All radiators are supplied with air vent valves.
Brackets: These room radiators are supplied with brackets.
The wall anchors and screws included in the wall fixing kit of the radiators are not suitable for all wall types. If necessary, use wall anchors, dowels and screws suitable for the existing wall. Please note that plasterboard and weak walls need to be reinforced properly before installing a radiator.
All radiators must be installed and maintained by a certified professional who provides legal guarantee for the work done. Neither the manufacturer nor our company can be held liable for improper installation.
Finish: High quality, environmentally friendly, double electrostatic powder coating according to DIN 55900.
WARNING! The floor standing version has to be fixed to the floor to prevent injuries.
See the technical drawing(s) HERE and HERE
SAFETY NOTICE
SAFETY NOTICE
In order to avoid accidents keep to the following safety regulations:
INSTALLATION AND MAINTENANCE OF RADIATORS
• All radiators must be installed and maintained by a certified professional, who provides legal guarantee for the work done.
• The radiators must be installed exclusively by certified fittings provided by the manufacturer.
• The radiator must be fixed soundly to the wall; as radiators are very heavy, torn out of the wall they can do extensive damage and seriously injure people nearby.
• Radiators can be fixed to walls that can carry their weight. Too thin and drywall walls must be reinforced by a professional before installation.
• Use the radiators strictly according to their purpose.
• Radiator holders are designed to safely carry the weight of the radiator; for this reason never put any extra weight on it, cling to it or lean, sit or stand on it even for a second.
• The radiator should not be placed behind or below furniture or other obstacle for the circulation of air.
• The radiator can be damaged by mechanical force caused by hard objects, so avoid this by all means.
• If you notice any damage, fracture, etc. on the radiator, switch it off immediately or turn off the heating. In the case of electric and dual fuel radiators disconnect the device from electricity.
HOT WATER RADIATORS
• Faulty or damaged radiators can leak hot water, which might cause serious burn injuries. In case you cannot wait until it cools down touch the hot radiator with utmost care.
CHILD SAFETY
• Unless the heating temperature is set low make sure that children are supervised near the radiator. As the body surface of a child is bigger than that of an adult, and their skin is considerably thinner, a hot radiator or hot water leaking from a damaged radiator can do more serious burn injuries to them.
• Some radiator models have sharp edges, which can also cause injuries to children. For this reason, if you live with children, or have children around unsupervised, install only radiators with rounded edges.
• Keep children away from the cord of the electric/dual fuel radiator. The best solution is wires hidden in the wall or the use of cord cover.
To open the safety notice in PDF click HERE